<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/">
  <dc:date>2025-12-01</dc:date>
  <dc:identifier>https://unilib.phaidrabg.rs/o:8578</dc:identifier>
  <dc:identifier>doi:10.18485/meattech.2025.66.3.9</dc:identifier>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:format>application/pdf</dc:format>
  <dc:format>1206519 bytes</dc:format>
  <dc:source>Meat technology - Special Issue 66/3 2025</dc:source>
  <dc:source>volume: 66</dc:source>
  <dc:source>number: 3</dc:source>
  <dc:source>startpage: 61</dc:source>
  <dc:source>endpage: 69</dc:source>
  <dc:creator id="https://orcid.org/0000-0001-9860-6681">Rašeta, Mladen</dc:creator>
  <dc:creator id="https://orcid.org/0009-0005-5844-9278">Branković Lazić, Ivana</dc:creator>
  <dc:creator id="https://orcid.org/0000-0002-3901-3824">Petronijević, Radivoj</dc:creator>
  <dc:creator id="https://orcid.org/0000-0001-8724-5892">Zsolt, Becskei</dc:creator>
  <dc:creator id="https://orcid.org/0000-0003-0301-729X">Jovanović, Jelena</dc:creator>
  <dc:creator id="https://orcid.org/0009-0006-9964-4317">Mrdović, Boris</dc:creator>
  <dc:creator id="https://orcid.org/0009-0001-7749-864X">Lukić, Mirjana</dc:creator>
  <dc:publisher>Institute of Meat Hygiene and Technology</dc:publisher>
  <dc:language>eng</dc:language>
  <dc:description xml:lang="eng">The objective of this work was to ensure all necessary prerequisites for exporting canned
fish meat (tuna pâté) to the United States market are met. To accomplish this, thermocou- ple measurements were conducted during sterilization in the autoclave to validate the heat treatment process. Initially, a temperature distribution study was carried out during regular production, followed by a heat penetration study. In both cases, the success criteria were satisfied. The temperature distribution was monitored using nine thermocouple probes, and within one minute after the holding time (come up time), the temperature at all measured points in the autoclave medium exceeded 120°C. For the heat penetration study, eleven probes were used, eight placed in the thermal centre of the cans and three in the autoclave medium. All probes located at the thermal centre achieved F0  values ranging from 6.88 to
8.56 minutes, confirming the safety and effectiveness of the sterilization process for tuna
pâté intended for export to the United States.
</dc:description>
  <dc:rights>http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode</dc:rights>
  <dc:subject xml:lang="eng">Sterilization, US import, Tuna pâté, Thermal distribution study, Heat penetration study</dc:subject>
  <dc:title xml:lang="eng">Fulfilling the requirements for exporting fish meat products (tuna pâté) to the United States market</dc:title>
</oai_dc:dc>