<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/">
  <dc:source>Annals of noninvasive electrocardiology(12952 (e12952))</dc:source>
  <dc:type>info:eu-repo/semantics/article</dc:type>
  <dc:date>2022</dc:date>
  <dc:creator id="https://orcid.org/0000-0002-3226-003X https://plus.cobiss.net/cobiss/sr/sr/conor/104886537">Babić, Miloš D., 1988-</dc:creator>
  <dc:creator id="https://orcid.org/0000-0002-2190-5701 https://plus.cobiss.net/cobiss/sr/sr/conor/10184551">Tomović, Milosav</dc:creator>
  <dc:creator id="https://plus.cobiss.net/cobiss/sr/sr/conor/76886025">Milošević, Maja</dc:creator>
  <dc:creator id="https://orcid.org/0000-0001-8336-2565 https://plus.cobiss.net/cobiss/sr/sr/conor/16399207">Đurđević, Branko</dc:creator>
  <dc:creator id="https://orcid.org/0009-0005-8871-5987 https://plus.cobiss.net/cobiss/sr/sr/conor/105058825">Žugić, Vasko</dc:creator>
  <dc:creator id="https://plus.cobiss.net/cobiss/sr/sr/conor/12785767">Nikolić, Aleksandra, 1969-</dc:creator>
  <dc:description xml:lang="eng">ABSTRACT:
We present a case report of a 74-year-old male patient with an implantable cardioverter defibrillator who suffered an inappropriate defibrillation shock while bathing in the tub. Insight in the ICD stored electrogram episodes revealed electromagnetic interferences, with a typical 50 Hz electrical artifact mimicking fast ventricular tachycardia as a device misinterpreted. After this event, the maintenance workers investigated the electrical installation in the bathroom and revealed that there was voltage leaking between electrical installation and metal pipes. After the repair was completed
without any additional programming, the patient has had no subsequent shocks.</dc:description>
  <dc:identifier>https://unilib.phaidrabg.rs/o:2818</dc:identifier>
  <dc:identifier>doi:10.1111/anec.12952</dc:identifier>
  <dc:identifier>cobiss:125664777</dc:identifier>
  <dc:identifier>ISSN: 1082-720X</dc:identifier>
  <dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode</dc:rights>
  <dc:subject xml:lang="eng">Key words: electrical installation, electromagnetic interference, implantable cardioverter defibrillator, inappropriate shock</dc:subject>
  <dc:format>application/pdf</dc:format>
  <dc:format>784925 bytes</dc:format>
  <dc:title xml:lang="eng">Inappropriate shock delivery as a result of electromagnetic interference originating from the faulty electrical installation</dc:title>
  <dc:language>eng</dc:language>
</oai_dc:dc>